第3回
Multi- Electrode Monitoring of Transient Anodic Events in SCC Initiation Stage: Methodology Development
著者:
Sujit BIDHAR,Yutaka WATANABE,T. UCHIMOTO
発刊日:
公開日:
キーワードタグ:
A new technique to monitor SCC initiation event has been developed by using electrochemical potential transients which can be used to locate the position of natural occurring SCC initiation sites, in 3 dimensional space. 6 titanium wire used as reference electrode , were placed around the test piece, SUS 316, in a way to cover maximum space around the test piece in order to record the potential transients that would be coming out as a result of SCC initiation event during slow strain test carried out in Na...
英字タイトル:
Multi- Electrode Monitoring of Transient Anodic Events in SCC Initiation Stage: Methodology Development